Permit: T01CM05196

Parcel: 11006006C

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/09/2002 FRAMING Approved IVRS - Inspection 0000*
01/04/2002 FRAMING Denied 1) DOUBLE SHEAR WALL 2 REQUIRES ANCHOR BOLTS AT 24" ON CENTER 2) FIRE BLOCK RANGE DUCT 3) FIRE BLOCK MASTER BEDROOM BY WATER CLOSET VENT MISSING 4) PROVIDE ARCHITECT AND CITY APPROVED TJI PLAN FOR ENTRY-ALL TJI'S MUST BEAR ON SUPPORTING MASTER BEDROOM 5) ANCHOR BOLTS REQUIRED WITHIN 12" OF SPLICES
12/31/2001 FRAMING Not ready for Inspection 1) NEED ANCHOR BOLT GARAGE SHEAR EXTERIOR WALL ( AT SPLICE) 2) BLOCK ALL MECH VENTS (2) ROMEX TO ALL EXHAUST 3) STRAP ACROSS DRYER DUCT TOP PLATE 4) MOVE OUTLET FROM UNDER KITCHEN COUNTER TOP 5) YOU NEED WATER IN TOP OUT SOIL TEST