Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
The login landing page when selecting 'View' is still occurring and is still pending further investigation.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/09/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/04/2002 |
FRAMING |
|
Denied |
1) DOUBLE SHEAR WALL 2 REQUIRES ANCHOR BOLTS AT 24" ON CENTER 2) FIRE BLOCK RANGE DUCT 3) FIRE BLOCK MASTER BEDROOM BY WATER CLOSET VENT MISSING 4) PROVIDE ARCHITECT AND CITY APPROVED TJI PLAN FOR ENTRY-ALL TJI'S MUST BEAR ON SUPPORTING MASTER BEDROOM 5) ANCHOR BOLTS REQUIRED WITHIN 12" OF SPLICES |
| 12/31/2001 |
FRAMING |
|
Not ready for Inspection |
1) NEED ANCHOR BOLT GARAGE SHEAR EXTERIOR WALL ( AT SPLICE) 2) BLOCK ALL MECH VENTS (2) ROMEX TO ALL EXHAUST 3) STRAP ACROSS DRYER DUCT TOP PLATE 4) MOVE OUTLET FROM UNDER KITCHEN COUNTER TOP 5) YOU NEED WATER IN TOP OUT SOIL TEST |