Permit: T01CM05194

Parcel: 136260620


Addresses:

2921 S QUINN DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T01CM05194

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
12/21/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
12/19/2001 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) SHEAR AT FRONT BEDROOM TO BE AS WIDE AS HOLDOWN. IT IS SUPPOSED TO BE ON THE OUTSIDE, SAME AS SHEARWALL 2) MISSING 4' OF NAILING ROOF AT FRONT BEDROOM 3) INSTALL A-35 ON INSIDE OF SHEAR 4) SHIM ALL 3 PT BEARING TRUSS INCLUDED GIRDER 5) OVERFRAMING AT GARAGE NOT PER PLAN