Permit: T01CM05150

Parcel: 128140620


Addresses:

5238 E 18TH ST

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
11/20/2001 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection 0000*ALL CORRECTION HAVE BEEN MADE.
11/09/2001 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection 0000*OK TO PROCEED OK TO SHEET ROCK RESTROOM CEILINGS.
11/08/2001 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection 0999*1.) PROVIDE 1" CLEARANCE AROUND FURNACE VENT PENETRATION THRU THE ROOF. 2.) PROVIDE EXHAUST FANS IN BATHROOM & SHOWER ROOM AS PER PLANS. 3.) COMBUSTIBLES NOT ALLOWED IN RETURN PLENUM UNDER FURNACE. 4.) PROVIDE AN EQUIPMENT SCHEDULE ON PLANS FOR HEATING EQUIPMENT. 5.) PROVIDE BACKING AROUND NEW CEILING & SIDEWALL REGISTER BOXES.