Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
Permit Number - T01CM05133
Inspection Description - PLUMBING - SEWER HCS CONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/22/2002 | PLUMBING - SEWER HCS CONNECT | Approved | IVRS - Inspection 0000*1.) 4" SDR BLDG SEWER OK WATER TEST OK 2.) TIE - IN TO EXISTING OK 3.) OK TO BACKFILL. | |
03/21/2002 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection 0999* 1.) BELL AND SPIGOT FITTING NOT INSTALLED PER LISTING FLOW IS FROM UPSTREAM BELL TO DOWNSTREAM SPIGOT THIS IS BACKWARDS. FLOW SHOULD BE FROM UPSTREAM SPIGOT TO DOWN STREAM BELL (SEE DIAGRAM.) |