Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 07/30/2003 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 07/03/2003 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*1) DRAFT STOP MECHANICAL PLUMBING 2) PROVIDE FULL BEARING CRIPPLES AT MECHANICAL PLUMBING WALL 3) NO GAS OR WATER BOND 4) PROVIDE D.W.V. TEST PER UPC SECTION 712.2 5) NAIL PROTECT ALL PLUMBING WITHIN 1 1/4" OF STUD/WALL SURFACE 6) LAUNDRY CANNOT BE "S" TRAPPED. USE SAN "T". 7) SUPPORT WIRES & DUCT AT 4' O.C. 8) NAIL ALL TABS ON TJI HANGERS |
| 04/22/2003 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000* |