Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/07/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 07/30/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) FRAMING INCOMPLETE 2) SEWER INCOMPLETE |
| 07/03/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*1) CLIP 4X8 BEAMS TO STUDS TO PLATE 2) CLIP PORCH TJE'S TO BEAM 3) PORCH COLUMN NOT BEARING 4) BLOCK ? BOOTS 3 SIDES 5) SUPPORT HEADER - NEED PLAN |
| 04/22/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) INSTALL FIREBLOCKS FURRDOWNS ETC.. 2) COMPLETE ALL TRADES THEN CALL FOR ALL INTERMEDIATES |
| 02/24/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |