Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM05118
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/20/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
02/14/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) BLOCK COMBUSTION/RELIEF STUD BAY IN GARAGE 2) CORRECT OVER NOTCHED STUDS IN ALL BEARING WALLS 3) GET DETAIL FOR FRONT TO BACK GLU LAM AT MID-GARAGE-REAR POST IS 2-2 X 4 ? 4) TIGHTEN HOLDOWNS 5) SUPPORT VENT 90 DEGREE IN MASTER PLUMBING 6) MOVE PEX 12" FROM CAN LIGHTS IN MASTER 7) REPAIR SOLE PLATE IN MASTER INTERIOR BEARING WALL 8) BANG PLATE ELFCTRIC AT KITCHEN SIDE OF MASTER BED WALL STUDS 9) PROVIDE 1" CLEARANCE TO COMBUSTIBLES AT FIREPLACE FLEX FLUE 10) SHIM BEARING HEADER TRIMMER WHERE NEEDED 11) NO HEADER TRIMMERS AT KITCHEN DOOR TO #2 AND 3 BEDROOMS NOTE: DRAINAGE TOPOUT OK ON 2/14 |