Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/14/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 02/07/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) LOOSE ROOF PANEL ABOVE MASTER BEDROOM (CHECK ENTIRE ROOF) 2) PROVIDE ENGINEERING FOR 2 MODIFIED TRUSSES AT REAR AND 4 AT FRONT BEDROOM 3) STRAP AROUND CORNERS WHERE TOP PLATES DON'T LAP 4) 45 DEGREE RETURN AT BACK DOOR MUST BE INCLUDED IN SHEAR APNEL (SEE PLAN) 5) PROVIDE PLAN FOR GARAGE/CASITA ( NO INSPECTION DONE IN GARAGE) 6) PROVIDE INSPECTION OPENING AT BASE OF COLUMNS |