Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM05090

Parcel: 133482550

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/16/2002 FRAMING Approved IVRS - Inspection 0000*
01/15/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) ITEMS 3 AND 5 FROM 1/11 INSPECTION NOT CORRECTED
01/11/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) FHA STRAP TOP PLATES AT GAS MAIN AND HVAC LINES IN GARAGE AND AT PLUMBING VENTS IN MASTER BATH. NAIL/SCREW ALL HOLES IN STRAPS 2) MOVE SMOKE DETECTORS AWAY FROM DUCT BOOTS-MINIMUM 3' 3) UNFINISHED ELECTRIC LINE AT MASTER TUB (SPA LINE), AND MASTER TOILET VENT FAN 4) NO KITCHEN SINK CLEANOUT 5) SECURE 3RD STRAP ON FIREPLACE CHIMNEY 6) SEAL HOLE IN PATIO LEDGER AT GAS LINE PROTRUSION 7) SEAL SLAB HOLE AT KITCHEN PLUMBING