Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/14/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 12/13/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NEED ADDITIONAL RED HEADS /SHOT IN REAR GARAGE WALL AND EXTERIOR WALLS AND TIGHTEN LOOSE ONES |
| 12/11/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) STRAP TOP PLATES AT GAS RISER 2) ADD RED HEADS 3) CORRECT TC CLIP NAILING 4) FIX TOP OF STOVE VENT |
| 12/07/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0950* |