Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T01CM05076
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/14/2002 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection 0000*OK ROUGH ELECT. | |
| 01/13/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*1.) SECURE CABLE ENTERING FLEX FOR AIR HANDLERS 2.) MOVE LIGHT OR PROTECT CABLE FOR FAN BOX #118. 3.) STRAP OR SECURE. CABLE WITHIN 12" OF CANS. 4.) FINISH DVD INSTALLATION DONT FORGET TO PROTECT CABLE THROUGH STUDS. | |
| 01/10/2002 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*1.) PROTECT NM CABLE LAYING ON SHARP EDGES OF STEEL STUDS 2.) SECURE NM CABLE STUD AND WITHIN 12" OF BOXES AND CANS 3.) PROTECT CABLE OR MOVE FAN BOX IN BEDROOM #118 4.) SECURE PANEL #122 OK PORCH LIDS TO ROCK. |