Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 03/22/2002 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 03/19/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0920*/ 1) NO ACCESS, 8:15 AM |
| 03/12/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0950*/ 1) OUTSIDE ELECTRIC OUTLETS CANNOT BE ON KITCHEN GFCI CIRCUIT 2) KITCHEN COUNTER GFCI OUTLETS MUST BE ON 2 EACH 20 AMP SEPARATE CIRCUITS 3) MAXIMUM ALLOWED FLEX GAS CONNECTOR ON WATER HEATER 36" 4) STOOP REQUIRED AT SLIDING GLASS DOORS-36" DEEP BY DOOR WIDTH 5) OUTSIDE HOSE BIBS REQUIRE ANTI-SIPHON VALVES 6) BEDROOMS HAVE NO HEAT. REVISE PLANS FOR ADDED REQUIRED HEAT 7) POST ADDRESS 906 #2 ON UNIT VISABLE FROM STREET |