Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM05004

Parcel: 141147460

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/27/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
11/26/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) NAIL BIRD BOARDS AT BACK BAYS AND RIGHT FRONT CORNER 2) ADD RED HEAD AT FRONT DOOR 3) A-35 TOP CORD OF STUB TRUSSES TO LEDGER OVER FRONT DOOR 4) STRAP FRONT DORMER GABLE TRUSS TO WALLS-GARAGE 5) BLOCK BOTTOM OF FRONT ENTRY COLUMNS AND TOP OF RIGHT COLUMN 6) STRAP FRONT DORMER HEADER 7) STRAP ENDS OF BOTH FRONT EYEBROW DORMER TRUSSES TO WALL 8) NEED LONGER STRAP ON 2 X 4 TOP PLATE WHERE REAR LEFT GARAGE WALL ATTACHES TO 2 X 6 WALL 9) TIE TOP CORD OF STUB GABLE TRUSS TO GARAGE (RAFTER TOP PLATES) ON LEFT SIDE