Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/03/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 11/30/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) GROUNDS NOT SCREWED IN PLACE 2) BLOCK VENT AT 3 SIDES 3) A.B. LOOSE THROUGHOUT HOUSE |
| 11/28/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NO GAS TEST 2 SECURE FURNACE AT ATTIC 3) MOVE WIRES AWAY FROM CAN LIGHTS 4) MOVE WIRES AWAY TRUSS GANG NAILS 5) SUPPORT CONDENSATE LINE 6 MISSING LTT 20 B AT GARAGE WALL 7) WILL NEED PERMIT FOR SALES OFFICE |