Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM04978

Parcel: 136032020


Addresses:

8310 E BOWLINE RD

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/03/2001 FRAMING Approved IVRS - Inspection 0000*
11/30/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) GROUNDS NOT SCREWED IN PLACE 2) BLOCK VENT AT 3 SIDES 3) A.B. LOOSE THROUGHOUT HOUSE
11/28/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) NO GAS TEST 2 SECURE FURNACE AT ATTIC 3) MOVE WIRES AWAY FROM CAN LIGHTS 4) MOVE WIRES AWAY TRUSS GANG NAILS 5) SUPPORT CONDENSATE LINE 6 MISSING LTT 20 B AT GARAGE WALL 7) WILL NEED PERMIT FOR SALES OFFICE