Inspection Status: Partial Approval
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/17/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000* |
| 05/13/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) GROUND ALL METAL ELECTRIC BOXES 2) CONNECT ALL GROUNDS IN ELECTRIC BOXES AND SECURE WITH MECHANICAL FASTENER 3) ALL ELECTRIC DEVICES MUST BE GROUNDED 4) ANCHOR BOLTS REQUIRED WITHIN 12" OF ALL SILL PLATE ENDS AND SPLICES 5) FIRE BLOCK ALL DROP CEILINGS 6) ALL WIRES MUST TERMINATE IN APPROVED ELECTRIC BOXES 7) SECURE ALL ROMEX CLAMPS 8) ELECTRIC AND MECHANICAL NOT COMPLETE 9) PROVIDE 10 FOOT WATER TEST ON ALL DWV PLUMBING 10) DOOR HEADER UNDER SIZED. PROVIDE DETAIL FROM CITY FOR INSTALLED STEEL |