Permit: T01CM04975

Parcel: 113061240


Addresses:

1630 E LIND RD

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
02/12/2002 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection 0000*
02/08/2002 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection 0999*/ 1) REVISE PLAN FOR CHANGE IN WIDTH FROM 17'-4" TO 18'-0" 2) PROTECT ALL PLUMBING THAT MAYBE IN CONTACT WITH CONCRETE EITHER WITH APPROVED SLEVE OR CLOSET WRAP 3) MAIN DRAIN FROM WATER CLOSET AND SHOWER CANNOT BE IN OR UNDER SLAB FOOTING. IT MAY RUN PERPENDICTULAR TO BUT NOT PARALLEL WITH FOOTING 4) ROUGH PLUMBING MUST HAVE A 10 FOOT HIGH COLUMN WATER TEST