Permit: T01CM04955

Parcel: 13701007Q


Addresses:

5680 S NOGALES HY

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/17/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*
1.) REVIEWED WORK WITH RICE PLUMBING CORRECTION ACCEPTABLE.
2.) OK FOR C OF O PENDING ANY OTHER INSPECTIONS.
04/10/2003 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*NOT READY FOR INSPECTION.
04/10/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*CROSS SECTIONAL AREA OF VENTING TO COMMERCE AT POINT OF VENT, WHERE CONNECTED TO TRAP ARM.
2.) MINIMUM SIZE OF CLEAN OUT FOR 3" SEWER IS 2 1/2" MINIMUM SIZE CLEAN OUT FOR 4" SEWER 3 1/2".
3.) CERTIFICATION OF RPPBP ON FILE W/TUCSON WATER.
04/01/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) PROVIDE CERTIFICATION OF RPPBP.
2.) AREA OF VENTING TO EQUAL LARGEST REQUIRED BLDG. SEWER.
3.) VENT TO ABOVE ROOF TO APPROVED MATERIAL.