Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/13/2002 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*1.) PLBG FINAL IS OK 2.) OK FOR C OF O. |
|
| 10/28/2002 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection 0000*OK FOR TEMP C OF O AS PER STEVE LONG. ONLY. | |
| 10/25/2002 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) MUST STRAP GAS LINE IN WATER HTR RM 2.) MUST SECURE EXPANSION TANK @ WATER HTR. 3.) MUST PROVIDE VACCUM BREAKER @ NORTH HOSE BIB. 4.) P-TRAP ON SHAMPOO SINK IS CANTED. 5.) MUST INSTALL DRYER OR CAP OFF GAS VALVE. 6.) MUST PERM CAP WASTE IN WALL FOR LAUNDRY SINK. 7.) MUST ANCHOR BACKFLOW PREVENTERS @ FONT SPA. 8.) CENTER SHAMPOO SINK REQUIRE VACCUM BREAKER 9.) MUST TEST & CERIFY BACKFLOW PREVENTERS FOR FOOT SPA. 10.) SI INTERCEPTOR REQUIRES ACCESS OR PIT. | |
| 10/24/2002 | PLUMBING - FINAL | Not ready for Inspection | PLEASE INSTALL ALL FIXTURE BEFORE CALLING FOR INSP. FOOT SPA WILL REQUIRE BACKFLOW DEVICE. |