Permit: T01CM04881

Parcel: 13609004A

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/05/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*PLBG. FINAL IS OK
2.) OK FOR C OF O.
04/22/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) H.C. LAVATORYS MUST MEET MIN STANDARDS OF ADA SPECS. HEIGHTS AND SIDE CLEARANCE
2.) H.C. URINAL LIP MUST BE 17" A.F.F. AS PER ADA SPECS. MAX.
3.) STANDARDS URINAL LIP MUST BE MAX 24" A.F.F.
4.) CRITICAL LEVEL FOR DISCHARGE TUBES FOR FLUSH VALVES MUST BE MIN 6" FROM C.L. TO TOP OF FIXTURE SEE SECTION: 603.3.1. 94 UPC.
5.) LOUNGE SINK TRAP ARM HAS MORE THAN (1) SLIP JOINT SEE SECTION: 1003.2. 94 UPC.