Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM04860

Parcel: 133554280

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/13/2001 FRAMING Approved IVRS - Inspection 0000*
12/12/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) SECURE WIRES AT RACEWAY AT GARAGE 2) SECURE GAS LINE THRU-OUT 3) SECURE PEX WATER LINES THRU-OUT 4) CHECK A.B.'S AND RED HEADS FOR TIGHTNERS 5) CHECK MAP ARM PITCH FOR VANITY'S AT MASTER BATH 6) BLOCK MECHANICAL 3 SIDES UPSTAIRS FURNACE 7) LEDGER AT 2ND FLOOR ABOVE ENTRY WAY A-35'S MISSING NAILS, ALL LEDGERS 2ND FLOOR