Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/29/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 11/27/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) BLOCK KITCHEN DUCT BOOT |
| 11/26/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NUMBERS 1, 3 AND 4 NOT DONE, SEE LAST INSP. SHEET |
| 11/21/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) BLOCK DUCT BOOT IN KITCHEN AND SEAL BOOT HOLE 2) STRAP TOP PLATES AT HALL BATH SINK VENT-INSIDE AND OUTSIDE 3) INSTALL TRUSS CROSS BRACING ABOVE KITCHEN 4) NO CLIP ON REAR RIGHT TRUSS AND TC CLIP MISSING NAILS AT REAR RIGHT 5) STRAP TOP PLATES AT MASTER VENT |
| 11/19/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NO MORE INSPECTIONS UNTIL LACK OF PRE-SLAB INSPECTION ISSUE GETS RESOLVED |