Permit: T01CM04840

Parcel: 136260630


Addresses:

2935 S QUINN DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/03/2001 FRAMING Approved IVRS - Inspection 0000*/ 1) FIX TRUSS IN GARAGE MISSING GUSSET NORTH END 2ND TO LAST, 1ST FROM GABLE
11/28/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) REMOVE COMBUSTIBLES AWAY FROM FLUE AT GARAGE FURNACE 2) CLIP NOT NAILED AT DOUBLE GABLE TRUSS GARAGE 3) LOOSE A.B.'S THROUGHOUT 4) BLOCK MECHANICAL 3 SIDES 5) STRAPABLE TOP PLATE KITCHEN
11/27/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) CANNOT LOCATE GAS PRESSURE TEST GAUGE 2) NEW DETAIL 6/DT1 ALL VERTICAL ATTACHMENT STUD SHEARWALL TO WALL CONNECTION VERTICAL 3) ALSO NEW DETAIL 10/DT1 SHEARWALL TRANSFER SEE A3.5 SCHEDULE SAME DETAIL