Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/10/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000*/ 1) USE A3.5 AT DRAG STRUT NOT R.S.P.'S |
| 12/07/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) DETAIL 10/DT1 SHEAR CONNECTION INTERIOR SHEAR 2) NEED 1/2 ANCHOR BOLTS AND 32" ON CENTER GARAGE SHEARWALL |