Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T01CM04839

Parcel: 136260660


Addresses:

2977 S QUINN DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T01CM04839

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
11/15/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*/ 1) PLAN CALLS FOR OSB AT SHEAR UP TO ROOF DECK 6/DT1 2) MISSING 8' OF NAILING ON ROOF DECK 3) 4' BLOCKING CANNOT FIND ON PLAN AROUND PERIMETER WALLS