Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/27/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 11/09/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) GARAGE FRONT SHEAR NAILING IS 4 AND 12, BECAUSE SHEAR PANELS AT GARAGE TO HOUSE WALL HAVE BEEN ELIMINATED 2) BROKEN OSB ON REAR GABLE, ONE TRUSS IS SHIMED PUTTING A HUMP IN THE ROOF 3) LARGE GABLE AT GARAGE VALLEYS NEED TO BE TRIMMED AND NAILED DOWN 4) MISSING VERTICAL 2 X 4 AT SOUTH GABLE TRUSS 5) WEDGES AT 3 PT BEARING, NEED FULL BEARING |