Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/15/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 11/14/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) CABLE END BRACING NOT PER PLAN PAGE A-8 DETAIL (3) 2) PROVIDE 1" CLEARANCE AT FLUE VENT GARAGE ROOF 3) PROVIDE 16 GUAGE AND 1.5 IN WIDE METAL-TIE ACROSS NOTCHES GREATER THAN 50 PERCENT OF BRG WALL TOP PLATE WITH 6-16 D NAILS EACH SIDE 4) PROTECT PEX AT DOUBLE WALL DINING ROOM KITCHEN 5) FIRE STOP COLUMN AT KITCHEN CEILING HEIGHT 6) INT BRG REQUIRE CLIPS PER PLAN |
| 11/13/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |