Permit: T01CM04830

Parcel: 129070950

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM04830

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/15/2001 FRAMING Approved IVRS - Inspection 0000*
11/14/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) CABLE END BRACING NOT PER PLAN PAGE A-8 DETAIL (3) 2) PROVIDE 1" CLEARANCE AT FLUE VENT GARAGE ROOF 3) PROVIDE 16 GUAGE AND 1.5 IN WIDE METAL-TIE ACROSS NOTCHES GREATER THAN 50 PERCENT OF BRG WALL TOP PLATE WITH 6-16 D NAILS EACH SIDE 4) PROTECT PEX AT DOUBLE WALL DINING ROOM KITCHEN 5) FIRE STOP COLUMN AT KITCHEN CEILING HEIGHT 6) INT BRG REQUIRE CLIPS PER PLAN
11/13/2001 FRAMING Denied IVRS - Inspection 0999*