Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM04822
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/04/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
12/03/2001 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) SECURE FURNACE FLUE 2ND FLOOR AND SEAL AT TOP PLATE 2) F/BLOCK MISSING SOUTH WALL MASTER BEDROOM AT PLUMBING VERTICAL 3) NO GAS TEST | |
11/30/2001 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) LOOSE ELECTRIC WIRE AT LAUNDRY CEILING 2) SECURE FURNACE FLUE 2ND FLOOR AND SEAL AT TOP PLATE 3) SECURE 4 GANG BOX AT MASTER BATH 4) NO GAS PRESSURE TEST | |
11/28/2001 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) DROP AT LAUNDRY MISSING 2) BLOCK DUCT FOR DEFFUSERS 3) A/C CONDENSATE MUST BE AT TRAY WITH AIR GAP 4) MISSING FIRE BLOCKING 5) SECURE FURNACE FLU 2ND FLOOR 6) NEED 1" CLEANCE AT WATER HEATER FLU AT 2ND FLOOR, STOPPED INSPECTION ( WATER TEST AT WASTE AND VERTS OK) |