Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/27/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 11/26/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) MISSING ANCHOR BOLTS AT GARAGE ENTRY 2 AT RIGHT SIDE ONE LEFT SIDE AND A.B.'S LOOSE 2) A.B. MISSING FRONT ENTRY 3) PROTECT ELECTRIC WIRES WITHIN 1 1/4 FROM EDGE OF STUD 4) SHIM BOTTOM OF HEADER AT KITCHEN WINDOW 5) HANGER MISSING AT GREAT ROOM RAFTER ABOVE FRONT DOOR AND WINDOW 6) SEE NUMBERS 3 AND 4 FROM 11/19/01 INSPECTION 7) SHIM ALL HEADERS AND CRIPPLES |
| 11/20/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |
| 11/19/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) SHIM HEADERS WHERE SPLIT AND THEIR TRIMMERS 2) INSTALL RED-HEADS AT PATIO DOOR AND ADD NUTS AND WASHERS WHERE NEEDED AND TIGHTEN ALL 3) H2.5 NEEDED AT SOUTHWEST RAFTERS 4) SHIM CRIPPLES WHERE NEEDED 5) REPAIR MECHANICAL SOFFIT IN LIVING ROOM 6) ADD BRACING IN GARAGE-TENSION 7) NO WATER PRESSURE 8) WEATHERPROOF DUCT THROUGH ROOF 9) INSTALL DAMPER VENT IN GARAGE |