Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T01CM04777
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/20/2002 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000*1.) ABOVE CEILING OK OK TO COVER 2.) INTERMEDIATE COMPLETE. | |
08/23/2002 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*1.) GAS PRESSURE TEST FOR 3" GAS LINE ABOVE CEILING AND 2" GAS DROPS FOR KITHCEN EQUIPMENT & WATER HTR SUPPLY. 2.) ALL VENT PENETRATIONS THRU ROOF ARE OK. | |
08/16/2002 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000* | |
08/07/2002 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*1.) NO TEE AT INTERCEPTOR DRAIN TERMINUS 2.) NO WATER TETST ON DRAIN LINE. 3.) TIE IN TO EXISTING COVERED. | |
07/31/2002 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*1.) TYPE "K" UNDERGROUND TO ISLAND FIXTURES OK 2.) O TO BACKFILL. 3.) OK FOR CONCRETE. | |
07/25/2002 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*1.) ABS DWV UNDERGROUND INSTALLED PER REVISION WATER TEST ONE TEN FOOT RISER. 2.) OK TO BACKFILL. 3.) DRAIN TO GREASE INTERCEPTOR. OK. | |
07/23/2002 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999* 1.) THE INSTALLATION OF DWV PIPING MUST BE ACCORDING TO APPROVED PLAN. PLAN NEEDS TO BE CLEAR SHOWING DRAIN AND VENT PIPING. 2.) CLEAN OUT TO BE FULL SIZE. | |
05/14/2002 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000*1.) PROVIDE APPROVED REVISED PLAN OR INSTALL AS PER APPROVED PLAN. PLEASE READ OVER INSP AS OF 4-29-02 INSTALL TRAPS PROPERLY PROVIDE TEST & CALL AGAIN DO NOT COVER. | |
04/29/2002 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*IT IS IMPORTANT THAT THE PLAN BE REFLECTIVE OF THE INSTALLATION. THE UNDERGROUND ABS WAS NOT APPROVED BY THIS INSPECTOR, AND THERE IS NO PLAN AVAILABLE TO SHOW HOW IT WAS INSTALLED. MAKE SURE REVISED PLUMBING PLAN SHOWS EXISTING PLUMBING AND HOW NEW PLUMBING IS CONNECTED. | |
04/17/2002 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999* 1.) PLEASE PROVIDE INSPECTION HISTORY FOR UNDERGROUND PLUMBING. 2.) NOT INSTALLED PER PLAN. | |
04/15/2002 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000*NOT READY FOR INSPECTION. | |
04/11/2002 | PLUMBING - INTERMEDIATE | Denied | FIXTURES HAVE BEEN ADDED WITHOUT REVISING PLANS. (SINKS) FITTING LEAKING AT HAND SINK. GREASE INTERCEPTOR INLET TOO HIGH FOR SEWER LINE. 10' HEAD FOR ROUGH SOIL INSP. OVERNOTCHED STUD IN MEN'S RESTROOM. |