Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T01CM04774
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/16/2001 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000*1.) ARCHETECT (JOHN FENECK) APPROVES ABS VENT 2.) PLUMBER ACHIEVED 2% ON SOIL PIPING 3.) ABS SUPPORTED EVERY FOUR FEET. 4.) COPPER SUPPORTED AT 6' INTERVALS 5.) OK TO COVER WALLS. | |
| 11/12/2001 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*1.) MET PLUMBER AT 10:00 AM AND REVIEWED CORRECTIONS FROM 10/26/01. SOME CORRECTONS HAVE BEEN MADE, MANY STILL NEED CORRECTION. WALKED THRU JOB W/PLUMBER 2.) STILL NEED LETTER FROM ARCHETECT ALLOWING INTERMINGLING OF MATERIAL. 3.)HAVE PLAN REVISED TO ALLOW 1% ON 4" DRAIN PIPING CORRECT BACKPITCH. CHECK URINA AND WATER CLOSET ELEVATIONS. | |
| 10/26/2001 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*1.) I WILL NEED TO SEE A LETTER FROM THE ARCHETECT STATING THAT IT IS OK TO INTER MIX ABS AND NO HUB PIPE. WHERE TRANSITIONS OCCUR (IF IT IS OKAY) APPROVED BANDS MUST BE USED IF ABS ACCEPTABLE, MUST BE SUPPORTED EVERY FOUR FEET MAXIMUM (HORIZONTAL) 2.) ONLY TWO FIXTURES ALLOWED ON 1/2" COPPER. 3.) TAPPED SANTEES IS MAY NOT BE INSTALLED SIDEWAYS 4.) A SANTEE IS NOT APPROVED ON ITS BACK 5.) NEED TO SEE A WATER TEST TO AT LEAST 10' ON DWV. 6.) WATER PIPING NOT INSTALLED PER PLAN 7.) MUST BE AT LEAST 6" ABOVE FLOOD RIM BEFORE OFF SETTING HORIZONTALLY. 8.) DRAINAGE PIPING TO BE INSTALLED AT 2% PITCH. 9.) A TRAP ARM MAY ONLY CHANGE DIRECTION 90 N/O A CLEAN-OUT. | |
| 10/12/2001 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000*1.) NO TEST 2.) SANTEE HORIZONTAL. 2.) SANTEE IN 3.) NO FORMAN ON JOBS. |