Permit: T01CM04757

Parcel: 122092120


Addresses:

4109 E WAVERLY ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/25/2002 FRAMING Approved IVRS - Inspection 0000*
02/15/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) TRUSSES CANNOT BEAR ON MASONRY WALL, MUST BEAR ON SILL PLATE SEE 1/3 2) MANY UNDER SIDE ANCHOR BOLTS NOT SECURE 3) MANY TRUSSES NOT CLIPPED 4) PROVIDE A COMPLETE DWV WATER TEST PER UPC 712.2 INCLUDING RELOCATED DRAINS 5) MECHANICAL IS NOT PER PLAN 6) REVISE PLAN AND HAVE APPROVED FOR ADDED GAS LINE 7) TRAP WEIR FOR LAUNDRY CANNOT BE HIGHER THAN 18" ABOVE FLOOR 8) PROVIDE 1/2" CLEARANCE TO WIRES AT RECESSED LIGHT 9) BLOCK DEFUSER 3 SIDES 10) PROVIDE GROUNDS FOR EACH LIGHT SWITCH 11) OUTSIDE LIGHTS AND SWITCH MISSING 12) NEXT FAILURE YOU WILL BE CHARGED A RE-INSPECTION FEE
02/01/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) FRAME OK BUT CANNOT APPROVE UNTIL ELECTRIC, PLUMBING AND MECHANICAL APPROVED
01/22/2002 FRAMING Denied IVRS - Inspection 0950*