Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 02/04/2002 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 02/01/2002 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ 1) HOUSE LOCKED/NO ACCESS |
| 01/18/2002 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ 1) 12 GUAGE AND 14 GUAGE WIRES CANNOT BE MIXED IN SAME CIRCUIT 2) ALL SWITCHES MUST BE GROUNDED 3) GROUND ALL METAL ELECTRIC BOXES 4) PROVIDE A MINIMUM 22 1/2 X 30 ACCESS TO ATTIC FOR INSPECTION OF ATTIC WIRING |
| 01/15/2002 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999*/ 1) DUCTWORK NOT INSULATED 2) OPEN ALL ELECTRIC OUTLET AND SWITCHES 3) EXTERIOR LAV VENT NOT PROPERLY INSTALLED-ABANDON AND INSTALL LAV OVERFLOW PLUG 4) PROVIDE ACCESS TO ATTIC 5) 3 PSI AIR TEST ON DWV 6) REVISE PLAN FOR ADDED REBUILT MECHANICAL SYSTEM 7) PROVIDE A 10 PSI AND GAS PRESSURE TEST 8) UNION REQUIRED AT FURNACE ON GAS LINE 9) FURNACE NOT PROPERLY SUPPORTED 10) EXPOSE LABEL ON FURNACE FLEX DUCT |