Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 03/22/2002 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 03/15/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) DELETE COVERED PATIO FROM PLAN 2) MECHANICAL METAL DUCT WORK NOT PROPERLY INSULATED 3) KITCHEN COUNTER OUTLETS BY RANGE MUST BE GFCI PROTECTED |
| 03/03/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999* |
| 02/11/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0950*/ 1) OUTSIDE HOSE BIB REQUIRES ANTI-SIPHON VALVE 2) PVC HOSE RISER MUST BE SUPPORTED AND PROTECTED ON METAL 3) PROVIDE ICBO/IAPMO LISTING ON DUCT INSULATION ON EXTERIOR DUCT 4) FILL IN SEWER TRENCH 5) SEAL WALL PENETRATION AT GAS LINE 6) LABEL ALL CIRCUITS IN ELECTRIC PANEL 7) ELECTRICITY MUST BE ON FOR FINAL INSPECTION 8) PROVIDE LADDER ACCESS TO INSPECT ATTIC 9) GAS LINE MUST BE ELECTRICALLY BONDED |
| 01/07/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) HOUSE HAS HAD ALL PLUMBING, MECHANICAL AND ELECTRICAL REPLACED INCLUDING SEWER AND DRAIN. PROVIDE PROOF OF INSPECTION OR EXPOSE ALL PLUMBING ELECTRICAL AND MECHANICAL 2) PROVIDE A COPY OF THE CURRENT PIMA COUNTY WASTE WATER SEWER FEES ON THIS PROPERTY |