Permit: T01CM04748

Parcel: 110101370


Addresses:

4982 E GARRISON CT

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/23/2002 FRAMING Approved IVRS - Inspection 0000*
01/09/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) FRAMING SLAB DAMAGE AT POST TENSION CABLE BROKEN, WAITING FOR ENGINEERING FIX OR REPORT, OK TO SHEETROCK
01/07/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) ZERO GAS TEST PRESSURE 2) NEED ENGINEER REPORT FOR BROKEN SLAB/AT FRONT CLOSET 3) SECURE COUNTER WALL (KITCHEN) 4) ADD STUD KITCHEN WALL OVER 24" ON CENTER 5) FIRE BLOCK AT FIREPLACE, NEXT TO SHELVING 6) BANG PLATE LAUNDRY TRAP ARM AND DRYER DUCT 7) BACKING AT TUB SIDES 8) REMOVE SCREW FROM INSIDE DRYER DUCT USE PLUMBERS TAPE 9) FIRE BLOCK AT LAUNDRY CEILING 10) CHECK ALL AB'S FOR NAIL PROTECTION 11) NEED ROOF FRAMING PLAN FOR THIS HOUSE
10/30/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) SAME AS LAST INSPECTION