Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/23/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/09/2002 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) FRAMING SLAB DAMAGE AT POST TENSION CABLE BROKEN, WAITING FOR ENGINEERING FIX OR REPORT, OK TO SHEETROCK |
| 01/07/2002 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) ZERO GAS TEST PRESSURE 2) NEED ENGINEER REPORT FOR BROKEN SLAB/AT FRONT CLOSET 3) SECURE COUNTER WALL (KITCHEN) 4) ADD STUD KITCHEN WALL OVER 24" ON CENTER 5) FIRE BLOCK AT FIREPLACE, NEXT TO SHELVING 6) BANG PLATE LAUNDRY TRAP ARM AND DRYER DUCT 7) BACKING AT TUB SIDES 8) REMOVE SCREW FROM INSIDE DRYER DUCT USE PLUMBERS TAPE 9) FIRE BLOCK AT LAUNDRY CEILING 10) CHECK ALL AB'S FOR NAIL PROTECTION 11) NEED ROOF FRAMING PLAN FOR THIS HOUSE |
| 10/30/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) SAME AS LAST INSPECTION |