Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM04747

Parcel: 112031600


Addresses:

2901 E HARDY PL

Inspection Status: Approved

Inspection History: BUILDING PRE-SLAB

Date Description Inspector Results Comments
10/31/2001 BUILDING PRE-SLAB Approved IVRS - Inspection 0000*
10/30/2001 BUILDING PRE-SLAB Denied IVRS - Inspection 0999*/ 1) SHOWER HAS "S" TRAP NOT ALLOWED 2) SHOWER HAS NO VENT3) TUB HAS "S" TRAP 4) ALL ROUGH PLUMBING MUST BEAR ON COMPACTED SOIL BRIDGING NOT ALLOWED 5) NO WATER TEST 6) ALL PLUMBING THAT WILL CONTACT CONCRETE MUST BE PROPERLY PROTECTED WITH CLOSET WRAP 7) NEXT FAILURE WILL BE CHARGED A RE-INSPECTION FEE I SUGGEST YOU GET A PLUMBER
10/29/2001 BUILDING PRE-SLAB Denied IVRS - Inspection 0999*/ 1) NO WATER TEST ON ROUGH PLUMBING-APPARENT LEAK AT "Y" 2) SHOWER TRAP AND TUB TRAP NOT INSTALLED