Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
| Date |
Description |
Inspector |
Results |
Comments |
| 10/31/2001 |
BUILDING PRE-SLAB |
|
Approved |
IVRS - Inspection 0000* |
| 10/30/2001 |
BUILDING PRE-SLAB |
|
Denied |
IVRS - Inspection 0999*/ 1) SHOWER HAS "S" TRAP NOT ALLOWED 2) SHOWER HAS NO VENT3) TUB HAS "S" TRAP 4) ALL ROUGH PLUMBING MUST BEAR ON COMPACTED SOIL BRIDGING NOT ALLOWED 5) NO WATER TEST 6) ALL PLUMBING THAT WILL CONTACT CONCRETE MUST BE PROPERLY PROTECTED WITH CLOSET WRAP 7) NEXT FAILURE WILL BE CHARGED A RE-INSPECTION FEE I SUGGEST YOU GET A PLUMBER |
| 10/29/2001 |
BUILDING PRE-SLAB |
|
Denied |
IVRS - Inspection 0999*/ 1) NO WATER TEST ON ROUGH PLUMBING-APPARENT LEAK AT "Y" 2) SHOWER TRAP AND TUB TRAP NOT INSTALLED |