Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T01CM04742
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/05/2001 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000* | |
10/03/2001 | PLUMBING - FINAL | Denied | 1.) INDIRECT WASTE PIPING REQUIRES 1" MINIMUM AIR GAP ABOVE FLOOR SINK. | |
10/02/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) INDIRECT WASTE PIPING FROM ICE BIN MAY NOT TERMINATE BELOW THE FLOOD RIM OF THE FLOOR SINK. SUPPORT HORIZONTAL PIPING FOUR FEET MAX. INDIRECT WASTE PIPING BETWEEN 5' - 15' SHALL BE TRAPPED. |