Permit: T01CM04742

Parcel: 13602002J


Addresses:

8240 E 22ND ST #111


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T01CM04742

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/05/2001 PLUMBING - FINAL Approved IVRS - Inspection 0000*
10/03/2001 PLUMBING - FINAL Denied 1.) INDIRECT WASTE PIPING REQUIRES 1" MINIMUM AIR GAP ABOVE FLOOR SINK.
10/02/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) INDIRECT WASTE PIPING FROM ICE BIN MAY NOT TERMINATE BELOW THE FLOOD RIM OF THE FLOOR SINK. SUPPORT HORIZONTAL PIPING FOUR FEET MAX. INDIRECT WASTE PIPING BETWEEN 5' - 15' SHALL BE TRAPPED.