Permit: T01CM04715

Parcel: 141147080

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/09/2002 FRAMING Approved IVRS - Inspection 0000*
01/08/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) BLOCK DUCT BOOTS 2) STRAP TOP PLATES AT FRONT DOOR WALL 3) FIX A-35 INSTALL AT ENTRY ROOF LEDGER 4) A-35 LEDGER IN 3RD CAR FOR ROOF TRUSS CONNECTION 5) SHIM HEADERS WHERE NEEDED 6) REMOVE RADIANT BARRIER FROM FLUES
01/04/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) A-35 TRUSS LEDGER ABOVE GARAGE GLUE LAM 2) WRONG GLUELAM/GLUELAM BRACKET 3) DOUBLE TRUSS AT GARAGE REAR IS NOT UNDER WALL ABOVE-SHEAR 4) NO BOOT BLOCKING
12/24/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*