Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/09/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 01/08/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) BLOCK DUCT BOOTS 2) STRAP TOP PLATES AT FRONT DOOR WALL 3) FIX A-35 INSTALL AT ENTRY ROOF LEDGER 4) A-35 LEDGER IN 3RD CAR FOR ROOF TRUSS CONNECTION 5) SHIM HEADERS WHERE NEEDED 6) REMOVE RADIANT BARRIER FROM FLUES |
| 01/04/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) A-35 TRUSS LEDGER ABOVE GARAGE GLUE LAM 2) WRONG GLUELAM/GLUELAM BRACKET 3) DOUBLE TRUSS AT GARAGE REAR IS NOT UNDER WALL ABOVE-SHEAR 4) NO BOOT BLOCKING |
| 12/24/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |