Permit: T01CM04714

Parcel: 138241920

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/02/2001 FRAMING Approved IVRS - Inspection 0000*
10/29/2001 FRAMING Denied 1) DOUBLE STUD REQUIRED UNDER GIRDER TRUSS AT GARAGE 2) FRAME AT GARAGE EAST WALL CONVERTS. TRUSSES TO 3 POINT BEARING HAVE TRUSS ENGINEER APPROVE AS BUILT 3) 1/2" BOLT REQUIRED 12" FROM PLATE EDGE, SOUTHWEST BED ROOM CLOSET 4) DOUBLE PLATE REQUIRED AT GARAGE WALL SHEAR SEE 8/A-2 5) COPY OF APPROVED TRUSS DRAWINGS REQUIRED ON SITE 6) MECHANICAL PLANS SHOWS OPENING IN CENTER OF MASTER BEDROOM REVISE PLANS OR COMPLY W/PLANS