Permit: T01CM04667

Parcel: 141147020

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/09/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
11/08/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) SEVERAL ROWS OF ROOF NAILING MISSING ON THE UPPER ROOF PLANES 2) ALL OF LOWER ROOF NOT NAILED 3) FRONT BEDROOM BOX TRUSSES NEED NAILERS FOR BRACKETS 4) EAST BOX TRUSS NEEDS H2.5 TO TRUSSES 5) NEED HORIZONTAL STRAP AT CANTILEVER TOP PLATES TO FRONT TRUSS BOTTOM CORD/PLATE 6) STRAP REAR RIGHT TOP PLATES AND REAR LEFT TOP PLATES 7) STRAP TOP PLATES AT FIREPLACE POP OUT 8) A-35 OR H2.5 FIREPLACE POP OUT ROOF LEDGER