Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/02/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 10/29/2001 |
FRAMING |
|
Denied |
1) SECURE WIRES BEHIND ELECTRIC SERVICE PANEL 2) REVISE MECHANICAL PLAN TO REFLECT AS BUILTS 3) HOW IS SHEAR TRANSFERED AT INTERSECTING WAU AT FUR/KITCHEN WALL 4) BLOCING MISSING AT SW5 AND SW4 5) DOUBLE TOP PLATE REQUIRED AT GARAGE SHEAR SEE 8/A-8 6) CHECK DETAIL 4/A-8 7) HAVE ARCH-OF RECORD CLARIFY CONNECTION AT HIP JACKS 8) STOPPED INSPECTION, HAVE SUPERINTENDENT WALK HOUSE PRIOR TO RECALLING FOR INSPECTION |