Permit: T01CM04611

Parcel: 111060130

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
09/20/2002 ROOF NAILING Approved IVRS - Inspection 0000*
01/11/2002 ROOF NAILING Partial Approval IVRS - Inspection 0000*/ 1) OK TO DRY IN
01/10/2002 ROOF NAILING Denied IVRS - Inspection 0999*/ 1) ROOF SHEATHIN MUST BE NAILED AT 6" ON CENTER FOR ALL SUPPORTED ENDS AND EDGES AND 12" ON CENTER IN FIELD 2) PROVIDE 2 X 8 BLOCKING BETWEEN RAFTERS AT EACH END 3) BOLT DOWN PLATES 4) INSTALL H2.5 CLIPS ON EACH END OF RAFTERS 5) REVISE PLAN AND HAVE APPROVED BY CITY OF TUCSON FOR CHANGE IN ROOF-RAFTERS INSTALLED-BEAR ON MASONARY WALLS AND ARE 2 X 10 6) NO. 2. DOUGLAS FIR SPANNING 15'-3"