04/30/2002 MECHANICAL - ABOVE CEILING Approved IVRS - Inspection 0000*
03/28/2002 MECHANICAL - ABOVE CEILING Partial Approval IVRS - Inspection 0000*1.) WATER HEATER T & P DRAIN LINE CANNOT TERMINATE ON TO THE ROOF. NEED TO SEE VENT PIPE & INSULATION SHIELD. YOU NEED TO HAVE PLUMBING INTERMEDIATE & PLUMBING FINAL ADDED TO YOUR PERMIT. OK FOR PARTIAL SHEET ROCK. MECHANICAL CORRECTIONS HAVE BEEN MADE. MECH CONTACTOR LICENSED.
03/20/2002 MECHANICAL - ABOVE CEILING Partial Approval IVRS - Inspection 0000* 1.) FLEX DUCT IN ATTIC MUST BE R-6 R4.2. WILL NOT BE ACCEPTED. 2.) WATER HEATER VENT MUST HAVE MIN 1' CLEARANCE FROM ROOF SHEATING MOVE FLEX DUCT FROM TOUCHING VENT PIPE. PROVIDE A THUMBLE AROUND VENT IN ATTIC EXTENDING 6" ABOVE ATTIC INSULATION. 3. MECHANICAL CONTRACTOR MUST HAVE A CONTRACTORS LICENSE TO WORK ON COMMERICAL PROPERTIES. PLEASE PROVIDE VERIFICATION 4.) FINISH INSTALLING DUCT WORK IN ATTIC.