12/11/2001 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*1.) VENT FOR GREASE TRAP IS OK 2.) OK TO BACKFILL TRENCH.
11/23/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*1.) SOIL WATER TEST FOR GREASE LINE & SANITARY BLDG. DRAIN IS OK 2.) OK TO BACKFILL TRENCH.
11/20/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) THIS INSPECTION IS FOR ROUGH PLBG. ON WEST SIDE OF BLDG. AND GREASE LINES. 3.) MUST CORRECT BACK PITCH ON 4" @ SOUTH SIDE OF BLDG. 4.) FLOOR SINK FLAT VENT MUST BE ABOVE CENTER LINE OF FLOW 5.) WILL REQUIRE A FLOOR C .O. WHERE 4" GREASE LINE EXCEEDS 135 RULE 6.)OK TO BACKFILL TRENCH OF SYSTEM APPROVED. 7.) RE TEST GREASE LINE UP TO TRAP.
11/19/2001 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*1.) NEED TO SEE WATER TEST ON ALL SECTIONS OF DWV PIPING TO AT LEAST 10' HEAD. 2.) HORIZONTAL CHANGES OF DIRECTION EXCEEDING 135' REQUIRES ADDITIONAL CLEAN OUT 3.) ACCEPTANCE OF ROUGH PLUMBING SUBJECT TO TRINI VALENCIA.
11/16/2001 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) P.O.C. OF NEW BLDG. DRAINS TO NEW 4" BLDG DRAIN IS OK 3.) NOTE: THIS INSPECTION IS FOR WASTE & VENT SYSTEM @ EAST SIDE OF BLDG. ONLY.4.) OK FOR BACKFILL EAST SIDE ONLY.