Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T01CM04515
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/11/2001 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection 0000*1.) VENT FOR GREASE TRAP IS OK 2.) OK TO BACKFILL TRENCH. | |
11/23/2001 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*1.) SOIL WATER TEST FOR GREASE LINE & SANITARY BLDG. DRAIN IS OK 2.) OK TO BACKFILL TRENCH. | |
11/20/2001 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) THIS INSPECTION IS FOR ROUGH PLBG. ON WEST SIDE OF BLDG. AND GREASE LINES. 3.) MUST CORRECT BACK PITCH ON 4" @ SOUTH SIDE OF BLDG. 4.) FLOOR SINK FLAT VENT MUST BE ABOVE CENTER LINE OF FLOW 5.) WILL REQUIRE A FLOOR C .O. WHERE 4" GREASE LINE EXCEEDS 135 RULE 6.)OK TO BACKFILL TRENCH OF SYSTEM APPROVED. 7.) RE TEST GREASE LINE UP TO TRAP. | |
11/19/2001 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection 0999*1.) NEED TO SEE WATER TEST ON ALL SECTIONS OF DWV PIPING TO AT LEAST 10' HEAD. 2.) HORIZONTAL CHANGES OF DIRECTION EXCEEDING 135' REQUIRES ADDITIONAL CLEAN OUT 3.) ACCEPTANCE OF ROUGH PLUMBING SUBJECT TO TRINI VALENCIA. | |
11/16/2001 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) P.O.C. OF NEW BLDG. DRAINS TO NEW 4" BLDG DRAIN IS OK 3.) NOTE: THIS INSPECTION IS FOR WASTE & VENT SYSTEM @ EAST SIDE OF BLDG. ONLY.4.) OK FOR BACKFILL EAST SIDE ONLY. |