Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T01CM04510
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/02/2001 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
11/01/2001 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) WRONG NAILS USED AT GIRDER TO TRUSS CONNECTION GARAGE 2) ID MAKE AND EQUIVALENT TO HUS26 HANGER GARAGE 3) HANGER FOR DETAIL 5/8A NOT SPECIFIED WRONG NAILS 4) NEED TRUSS SHOP DRAWINGS ON SITE 5) MINIMUM #10 TECO NAIL AT AND SC TRUSS CLIPS REAR WALL 6) MISSING NAILING ON MIDDLE DORMER ROOF FRONT 7) TRUSSES NOT BLOCKED AT REAR PORCH 8) FRONT GABLE CONTINOUS BEARING TRUSS NOT SUPPORTED 9) RENAIL TRUSS CLIPS AT REAR TUB 10) NEED PERIMET NAILER AT FRIEZE BOARDS FRIEZE BOARDS AR TO SMALL 11) SHEAR WALLS ON SOUTH SIDE TO CONTINUE UP TO ROOF AND DECK 12) NEED SIMPSON CSZ0 STRAP ACROSS BEAM AND SHEAR AT GARAGE DETAIL 503 | |
10/30/2001 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) REPLACE BIRD BOARD FRONT OF HOUSE 2) FIX DOUBLE PLATE NORTH WEST CORNER 3) STRAP ALL CORNERS FOR POSITIVE CONNECTION 4) PORCH TO WALL CONNECTION CALLS FOR H2.5'S 5) STRAP SHEARWALL SOUTHSIDE 6) LOOSE AB'S THRU-OUT |