Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T01CM04497
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/11/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
01/09/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) PARAPET MUST EXTEND A MINIMUM OF 30" ABOVE ROOF IN ALL WALLS 2) 2 EACH GROUND RODS REQUIRED 8 FEET LONG DRIVEN TO GRADE AND AT LEAST 6 FEET APPART CONNECTED TO SERVICE PANEL WITH A CONTINOUS #4 WIRE 3) SUB PANEL WILL REQUIRE AN ISOLATED NEUTRAL BAR 4) PROVIDE GROUND PIG TAILS FOR ALL SWITHCES AND OUTLETS 5) GROUP ALL METAL ELECTRIC BOXES. LOCK NUTS NOT ALLOWED AS GROUND 6) BX CABLE NOT PROPERLY SECURED 7) A/C CIRCUIT NOT INSTALLED |