Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM04468

Parcel: 117071910


Addresses:

124 W 18TH ST 02

Inspection Status: Approved

Inspection History: PLUMBING - SEWER HCS CONNECT

Date Description Inspector Results Comments
12/10/2002 PLUMBING - SEWER HCS CONNECT Approved IVRS - Inspection 0000*1.) SEWER/HCS CONNECTION OK
2.) TRANSITION FITTING OK
3.) OK TO COVER.
11/25/2002 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection 0000*1.) BLDG #2,#3,#4,#5 SEWER FROM PREVIOUSLY INSPECTED HCS CONNECTION TO BLDG TIE INS OK. SDR 35 WATER TEST OK
2.) THIS INSPECTOR QUESTIONS BACK WATER VALVE.
PLEASE CHECK OVERFLOW OF UPSTREAM MANHOLE.
ONLY FIXTURES WITH FLOOD LEVEL RIMS LOCATED BELOW UPSTREAM MANHOLE SHALL DISCHARGE THROUGH BWV.