Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/09/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 11/08/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) REPLACE ALL ROTTED OSB ON EAST GARAGE ROOF PLANE 2) KERF OVER LAPPED ROOF OSB-WEST OF ENTRY DORMER 3) MISSING STUD CLIPS AT SOME CORNERS 4) STRAP IS TO SHORT AT REAR RIGHT TOP PLATES 5) H2.5 ALL PATIO ROOF RAFTERS TO TOP PLATE 6) PROPERLY INSTALL A-35'S ON LOWER LEDGER OVER FRONT DOOR |