Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/07/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 11/13/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) LEAVE SPECIFICATIONS FOR DIRECT VENT FIREPLACE 2) CHECK VENT TERMINATION DISTANCES TO COMBUSTIBLES EXTERIOR WALL AND ROOF/PORCH 3) CHECK FOR FRAMING OPENING AT VERTICAL WALL FLUE PENETRATION |
| 11/09/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NUMBERS 3 AND 7 NOT DONE |
| 11/08/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NUMBERS 5 AND 7 NOT DONE 2) NEED PREVIOUS INTERMEDIATE INSPECTION SHEET |
| 11/05/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*1.) REMOVE 2ND NAIL IN SLOT OF TC CLIP NEXT TO A/C LINES 2. BLOCK PLENUM 3.) BLOCK LAUNDRY DUCT BOOT. 4.) MOVE SMOKE DETECTOR FURTHER FROM DUCT BOOT 5.) GROUT HALL TUB DRAIN BOX 5.) PROVIDE INSTALLATION SPECS FOR FIRE PLACE 6.) TIGHTEN ANCHOR AT REAR PATIO DOOR AND OTEHR 7.) FHA STRAP TOP PLATES AND KIT VENT. |