Inspection Status: Approved
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/26/2001 |
ROOF NAILING |
|
Approved |
IVRS - Inspection 0000* |
| 11/25/2001 |
ROOF NAILING |
|
Denied |
IVRS - Inspection 0999*/ 1) SEVERAL LOOSE AREAS ON ROOF 2) GABLE END TRUSS IN GARAGE NOT BRACED PER PLAN (SEE DETAIL B) 3) BLOCK EDGES OF SHEATHIN GREATER THAN 12" WIDE |