Permit: T01CM04374

Parcel: 13303277B

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/06/2002 FRAMING Approved IVRS - Inspection 0000*
02/22/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) ITEMS #1 AND #3 NOT COMPLETED
02/20/2002 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) INSTALL PLATFROM IN FRONT OF ATTIC FURNACE AND SHEETMETAL IN FRONT OF FIREBOX AREA 2) INSTALL POSITIVE CONNECTION PORCH BEAM TO EXISTING MASONRY 3) INSTALL SECONDARY DRAIN PAN ATTIC UNIT